Buying the panels is the easy part. You choose a device, you choose a plan, and it arrives. Then somebody asks where the power is coming from, whether the glass wall can be drilled, and who is paying the electrician. That is usually the point where a meeting room display project slows down.


None of it is hard. It just has to be decided before the devices land on your desk, because most of the decisions involve someone other than you. Your facilities team, your IT team, your landlord and sometimes your interior designer all have a say.


Below, we discuss the factors you have to settle before you mount a meeting room display panel, and where each one tends to go wrong.


1. The Type of Meeting Room Display Panel


Everything else follows from this, so decide it first. You have two routes.


Commercially available tablets

Android tablets and iPads bought from any supplier. The advantage is cost and availability. You can buy them anywhere, replace them quickly, and you are not tied to one vendor. The downside is that they arrive with nothing else. No mount, no LED, no card reader, no wired network. You solve all of that separately.


Purpose built room panels

Devices designed to sit outside a door and do nothing else. They usually run Android or Windows, and they typically include the enclosure and mounting kit, an Ethernet port with Power over Ethernet, LED status lights along the edge, and an NFC or RFID reader for staff card check-in. Some have no battery at all, which makes them lighter and less prone to heat problems when they are on for years at a time.


Which to choose

For a small rollout, or a pilot, use commercial tablets. For a large estate, or where you want card check-in and corridor visible LEDs, price up purpose built panels properly before dismissing them. Once you add a decent enclosure, an Ethernet adapter and a mounting kit to a consumer tablet, the gap narrows.


2. Casings and Mountings


If you go the commercial tablet route, the casing is a separate purchase. These range from basic enclosures that solve nothing except holding the device, up to designed casings with cable management, lockable fronts, LED strips and even network adapters built into the frame.


The interesting thing about the expensive casings is that they close most of the feature gap with a purpose built panel. You can get LED status and Ethernet on an iPad. You just pay for it, and you pay per door.


Purpose built devices usually ship with the enclosure and the mounting plate as part of the product. There is nothing else to order and nothing else to wait for, which matters more than it sounds when you are trying to coordinate an installation date.


3. Power Cable Layouts


Every panel needs power. In most offices the supply comes from above the false ceiling, and in some buildings, data centres in particular, it comes from under a raised floor.


You have to get hold of the office schematics. You are looking for where the existing runs go and where you can branch off them. Guessing is expensive, because the cost of the install is mostly labour and making good afterwards.


One useful shortcut. If the meeting room already has card access or a magnetic door lock, there is almost certainly a power run near the top or the bottom of that door frame already. Running a parallel line to your mounting point from there is far cheaper than starting a fresh run from the riser.


4. Power over Ethernet


With Power over Ethernet, the RJ45 cable carries data and power on one run. One cable per door instead of two. That is genuinely tidier, and it is the reason most large installations end up here.


Two things to check. First, your switch has to support it. If it does not, budget for a PoE capable switch or for injectors, and remember injectors need somewhere to live. Second, distance. The practical limit on a PoE run is somewhere around 70 to 100 metres depending on the voltage, the cable grade and how much the run is loaded. Push past that and you lose power to attenuation before you lose the data signal, and the Ethernet standard caps you at 100 metres anyway.


Direct power or PoE, which to choose?

Direct mains power is simpler, cheaper on a small job, and does not care about your switch. The downside is a second cable run and, often, a visible plug. PoE is cleaner and easier to manage across a big estate, and it lets you reboot a panel remotely from the switch. The downside is the upfront switch cost and the distance limit. If you are running more than about twenty panels, PoE usually wins.


5. Wi-Fi Coverage


If your device has no Ethernet, and most consumer tablets do not, you are on Wi-Fi. Two things matter and both are worth a survey.


Dead zones are the first. Meeting room doorways sit in corridors, often behind lift cores and service risers, and the signal there is frequently worse than in the open plan area you measured from. A panel in a dead zone drops out, shows stale information, and fails bookings at the moment someone is standing in front of it. That is the fastest way to lose your users' trust in the whole system.


Bandwidth is the second, and it is less of a problem than people fear. Panels poll for schedule changes, so the traffic per device is small. What matters is the number of associated clients on the access point covering that corridor, not the volume of data. Once you are past roughly twenty panels in a building, talk to whoever owns the wireless network before you install rather than after.


6. Aesthetics


Somebody in your organisation cares deeply about how the wall looks, and you will meet them eventually. Bring them in early.


The colour question is usually simple. White casings disappear against white walls and plasterboard. Black casings sit better against wood, dark glass frames and exposed concrete. Most vendors offer black, white and silver, so match to the door frames rather than the walls if the two differ.


The mounting depth question is harder. Flush mounting, where the panel sits level with the surface, looks best and is the most expensive. Semi recessed is a reasonable compromise. Surface mounting is cheapest and perfectly acceptable. Flush and semi recessed work in stud partitions where you can open up the wall. They are impractical in solid concrete and impossible in a single pane of glass.


Think about servicing too. A panel that is beautifully flush and sealed into the wall is a problem the day it has to come out.


7. The Mounting Surface


The surface decides the fixing method.


- Glass. Industrial adhesive on a faceplate, not screws. Drilling glass is possible but it is precision work, and a mistake means replacing the whole pane.

- Stud partition. Screws into the plasterboard with the right fixings, or adhesive if the board is thin. Thickness matters more than people expect.

- Concrete or brick. Screws and plugs. Surface mounting only.

- Wood and metal door frames. Usually the easiest. Frames are often thick enough to conduct the cable inside and hide the exit point behind the panel.


Site Survey Specifications

Item

What to confirm before install

Panel type

Commercial tablet or purpose built panel, model confirmed

Enclosure

Included with device, or ordered separately with matching mount

Power method

Direct mains or Power over Ethernet

PoE run length

Under 100 m from switch, ideally under 70 m

Switch capability

PoE budget available on the relevant switch

Wi-Fi

Signal measured at the door, not in the open plan area

Mounting height

1.3 m to 1.5 m from finished floor level

Mounting position

Door side opposite the hinges

Surface

Glass, partition, concrete, wood or metal frame

Finish

Casing colour agreed against door frames and walls

Making good

Who patches and repaints, and when




Wrapping Up


Mounting a meeting room display panel is a coordination job more than a technical one. The device type drives the casing, the casing drives the mount, the mount drives the cable route, and the wall decides what is actually possible.


A law firm taking one floor of a fitted building is a good example. The rooms are all floor to ceiling glass, so drilling is out, the panels go on adhesive faceplates, and the cable comes down inside the aluminium door frames. That one decision, made during the site survey rather than on installation day, is the difference between a clean job and a fortnight of arguing with the landlord.


Walk your floor with this list before you order anything. If you want a second opinion on a tricky wall, talk to us and we will go through it with you.

Frequently Asked Questions


How high should a meeting room display panel be mounted?

Between 1.3 and 1.5 metres from the floor, so it is comfortable to reach standing or from a wheelchair.


Which side of the door should it go on?

The side opposite the hinges. You want people to read it and tap it without standing in the door swing.


Can I mount a panel on a glass wall?

Yes. Use an industrial adhesive faceplate rather than drilling, and run the cable down the door frame.


Do I need Power over Ethernet?

No, but it is tidier at scale. One cable per door, and remote reboots from the switch. Direct mains power is fine for small rollouts.


How long can a PoE cable run be?

Keep it under 100 metres, and under 70 metres if you want headroom. Beyond that you lose power to attenuation.


How many panels can my Wi-Fi handle?

The data volume is small. Client count on each access point is the real constraint, so review coverage once you pass about twenty panels in a building.


Does the casing need to match our office colours?

It helps. Most casings come in black, white or silver. Match the door frames rather than the wall if they differ.